Hp agilent 34970a manual

Agilent 34970a34972a data acquisitionswitch unit note. Jul 31, 2014 connecting to a 34970a with rs232 and connecting to 34972a data acquisition unit with lan. Warranty services outside the country of initial purchase are included in agilent s product price, only if customer pays agilent international prices defined as destination local currency price, or u. Please send the 34970a into a keysight service center to be calibrated and they will replace the battery. The table below shows the general environmental requirements for this instrument. View and download agilent technologies 34970a manual online. Agilent 33120a 15 mhz function arbitrary waveform generator note. Keysight 34970a34972a messdatenerfassungs schaltsystem. Data loggers, or data recorders, collect information over time for a variety of purposes. This page lists hp and agilent scanned manuals that may be out of print. Instrument locked by another io session 34972a only 521 communications. Unless otherwise indicated, this manual applies to all serial numbers.

Using the agilent 34970a with labview national instruments. Connecting to a 34970a with rs232 and connecting to 34972a data acquisition unit with lan. Three module slots are built into the rear of the instrument to accept any combination of data acquisition or switching modules. Download free hp user manuals, owners manuals, instructions, warranties and installation guides, etc. Agilent 34970a data acquisitionswitch unit product overview agilent performance at a fraction of the cost of other standalone data acquisition systems. Read and download hp switch hp 34970a users manual page 424 online. Keysight 34970a34972a data acquisition switch unit. The keysight 34903a is a generalpurpose switch module for the 34970a 34972a data acquisitionswitch unit. Connecting to a 34970a with rs232 and connecting to 34972a. The keysight 34970a data acquisition data logger switch unit consists of a threeslot mainframe with a builtin 6 12 digit digital multimeter. Each channel can be configured independently to measure one of 11 different functions without the added cost or hassles of signalconditioning accessories. Choose from eight optional plugin modules to create a compact data logger, fullfeatured data. Its flexible, modu lar design makes it scalable from 20 to 120 chan nels, and lets you add.

Agilent delivers complete scientific solutions, helping customers achieve superior outcomes in their labs, clinics, business and the world they seek to improve. Ive seen at least 20 34970s with dead frams in the dmm module. Data logger pro software for the 34970a, 34972a and 34980a flow diagrams, sequencing. Once configured, agilent connection expert is used to create a connection with the instrument. Error messages keysight 34970a34972a documentation. The agilent technologies 34970a34972a combines precision measurement capability with flexible signal connections for your production and development test systems. The agilent 34907a module for the 34970a34972a data acquisitionswitch unit allows great flexibility for a variety of sense and control applications. Keysight 34970a34972a service guide 7 environmental conditions the 34970a34972a is designed for indoor use and in an area with low condensation. The 34970a data acquisition data logger switch unit consists of a threeslot mainframe with a builtin 6. Nov 14, 2018 data acquisition 34970a, 34972a, benchvue. Environmental condition requirement temperature operating condition 0 c to 55 c humidity operating condition. Chemical analysis, life sciences, and diagnostics agilent.

This document contains references to agilent technologies. The keysight 34907a module for the 34970a 34972a data acquisitionswitch unit allows great flexibility for a variety of sense and control application. Agilent 34970a is a highperformance, lowcost data acquisition and switching mainframe idea for data logging, data acquisition, and general purpose switching and control applications. The 34970a is an automated test system with excellent measurement performanceits got the.

Customcal offers discount test equipment repairs service and calibrations on agilent 34970a, including hp agilent 34971a. For more information, go to this help file contains reference information to help you program the. Agilent 34970a messdatenerfassungs schaltsystem farnell. Benchlink data logger pro software download for 34970a and.

Keysight agilent hp 34970a data acquisitionswitch unit. Database contains 1 agilent technologies 34972a manuals available for free online viewing or downloading in pdf. Hp agilent diagrams, schematics and service manuals download for free. Agilent hp 3450a service manual english service manual agilent hp 3450a this service manual or workshop manual or repair manual is the technical document containing instructions on how to keep the product working properly. The keysight 34970a data acquisition data logger switch consists of a threeslot mainframe with a builtin 6 12 digit digital multimeter. Nov 01, 2014 the 34970a is completely useless until it is recalibrated and new cal constants are stored. No part of this manual may be reproduced in any form or by any means including elec. The agilent technologies 34970a34972a combines precision measurement capability. Keysight agilent 34970a data acquisitionswitch unit. The agilent 34970a consists of a threeslot mainframe with a builtin 6 12 digit digital multimeter option 001, removes the dmm.

The agilent 34970a offers unequaledversatility for your. Hp agilent original service operating manuals for test. Keysight agilent 4934a in stock, we buy sell repair. Agilent 34970a, battery replacement and repair page 2. Publication number 3497090003 order as 3497090101 manual set. The lithium battery is soldered in place and you should not try to replace it. For more information, go to this help file contains reference information to help you program the keysight 34970a 34972a over a remote interface using the programming language.

How to check the relay cycle counts on an agilent 34970a and. F or additional important information about serial numbers, read \serial number in appendix a. Agilent performance at a fraction of the cost of other. Agilent technologies 34972a manuals and user guides, switch. It covers the servicing, maintenance and repair of the product.

The agilent hp 4934a transmission impairment measuring set increases installation and maintenance productivity for telephone companies and service providers through its ease of use, portability, and ruggedness. A data logger uses internal memory and sensors to gather and document information on a 24hour basis. Manual part number 3497090003, june 2006 order as 3497090101 manual set edition edition 4, june 2006 edition 3, march 2003 edition 2, october 1997 edition 1, july 1997 printed in malaysia agilent technologies, inc. Agilent intuilink arb waveform generation software for microsoft windows warning the procedures in this manual are intended for use by qualified, servicetrained personnel only. Using a soldering iron on a lithium battery is very dangerous. The agilent technologies 34970a combines precision measurement capability with. Scored on 34901a 20 channel multiplexer 24wire module this is the most universal module for 34970a. You can order any of these manuals directlyl from us. Oct 26, 2015 these orignal frams were made by seiko. It has 20 independent singlepole, doublethrow spdt relays and is used to cycle power to products under test, control indicator and status lights, and to actuate external power relays and solenoids. It combines two 8bit ports of digital input and output, a 100 khz gated totalizer, and two 12v analog outputs all on a single earterenced module.

Thousands of instrument drivers, including the driver for the agilent 34970a, are available for free download from. Dmm for precision measurements easytoread display to monitor the setup and measured values easytouse front panel for manual setup control 34970a computer interfaces. Agilent hp 34970a data acquisitionswitch unit manual set pn 3497090100 new. Introduction to the 34970a instrument driver an instrument driver is a set of software routines that control a programmable instrument.

Keysight 34970a34972a over a remote interface using the programming language. The procedures in this manual are intended for use by qualified, servicetrained personnel only. User manuals, guides and specifications for your agilent technologies 34972a switch. Agilent took the measurement engine from their bestselling benchtop dmm and embedded it inside a 3slot cardcage. Started with check according to service manual and found that five relays does not work k107k111. Hp keysight agilent agilent hp 34970a data acquisition. Agilent s former test and measurement business has become keysight technologies. Free hp agilent diagrams, schematics, service manuals.

634 523 697 917 1066 518 469 83 1494 159 1038 922 1253 210 1522 664 892 957 574 981 532 183 1100 609 526 75 468 1427 898 141 537 1202 705 128 745 447 1012